Processor |
Number |
Up to two dual-processor CPU/Memory Boards (2 or 4 CPUs) |
Architecture |
900-MHz, 1050-MHz, or 1200-MHz UltraSPARC III Cu |
Cache memory |
64-KB data and 32-KB instruction
Secondary: 8-MB external |
Main Memory |
Capacities |
8 memory slots (DIMMs) per processor, 16 total slots per CPU/Memory Board
256-MB, 512-MB, or 1-GB expansion (16GB maximum per CPU/Memory board, 32GB maximum when configured with 4 processors)
Note: Install DIMMs in groups of four. 1050MHz & faster CPU/Memory boards require that all memory DIMM slots be fully populated. |
Standard Interfaces |
Ethernet |
Two 10/100/1000BASE-T twisted-pair ethernet ports (RJ-45) |
FC-AL |
One Fibre Channel Arbitrated Loop (FC-AL) high-speed serial data connector (HSSDC) |
Keyboard and mouse |
USB |
PCI |
Six PCI slots compliant with PCI specification Revision 2.1:
- Two slots (0 & 1) operating at 66-MHz, 64 bits wide, 3.3 volts (full length slots)
- One slot operating at 33-MHz, 64 bits wide, 5 volts (full-length slot)
- Three slots operating at 33-MHz, 64 bits wide, 5 volts (short slot)
|
Remote System Controller |
One RSC card plugs into a dedicated slot on the system I/O board which includes integrated modem, serial and Ethernet interfaces.
- One 56 Kbps modem port (RJ-11)
- One EIA-232D serial port (RJ-45)
- One 10 Mbps Ethernet port (RJ-45)
|
Serial |
One RJ45 serial port |
USB |
Two standard Universal Serial Bus (USB) Type A connectors |
Internal Mass Storage |
Disks |
Two front-accessible, hot-swappable, FC-AL disks, 36-GB, 73-GB or 146-GB, 3.5-in. x 1.0-in. 10,000 RPM |
DVD-ROM |
8x DVD-ROM (IDE) drive |
Power Supplies |
Type |
One required, two for N+1 redundancy (hot swap), each with independent power cord |
Output |
560 W per power supply |
Environment |
AC input |
100 - 240 VAC, 50 - 60 Hz, 8.6 A(max) |
Input power |
1100 W (max) |
Heat output |
3751 BTU/hr (max)
|
Temperature |
Operating: 5¡Æ C to 35¡Æ C (41¡Æ F to 95¡Æ F) Nonoperating: -20¡Æ C to 60¡Æ C (-4¡Æ F to 140¡Æ F) |
Humidity |
Operating: 20%to 80% relative temperature humidity, noncondensing Nonoperating: 5% to 95% relative temperature humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.) Nonoperating: 12,000 m (40,000 ft.) |
Acoustic noise |
Operating: 74.5 dBA Idling: 74.5 dBA |
Vibration |
Operating: .0002 G/Hz, 5 - 500 Hz (random) (deskside) .0001 G/Hz, 5-150 Hz, -12db/octave slope 150-500 Hz (z-axis only) (rackmounted) Nonperating: .002 G/Hz, 5 - 500 Hz (random) (deskside) .001 G/Hz, 5-150 Hz, -12db/octave slope 150-500 Hz (z-axis only) (rackmounted) |
Shock |
Operating: 4G peak, 11 milliseconds half-sine pulse (deskside) 3G peak, 11 milliseconds half-sine pulse (rackmounted) Nonoperating: 15G peak, 11 milliseconds half-sine pulse (deskside) 10G peak, 11 milliseconds half-sine pulse (rackmounted) |
Number of cords |
2 (max) |
1 Refers to total input current required for both AC inlets when operating with dual power supplies or current required for a single AC inlet when operating with a single power supply. |
Regulations Meets or exceeds the following requirements: |
Safety |
UL 60950, CSA C22.2 EN 60950 (from U.L.), TUV 60950, UL CB scheme IEC 950 (CE mark), GOST |
RFI/EMI |
Class A:Australia/New Zealand AS/NZ 3548, Industry Canada ICES-003, European Community EN55022/CISPR22, Japan VCCI, Taiwan CNS 13438, and US FCC 47CFR15.B |
Immunity |
EN55024, EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-11, IEC 61000-3-2, and IEC 61000-3-3 |
X-ray |
U..DHHS 21CFR Subchapter J,PTB German X-ray Decree |
Dimensions and Weights |
Height |
22.2 cm (8.75 in.), 5 Rack Units |
Width |
44.6 cm (17.5 in.) |
Depth |
61.0 cm (24.0 in.) |
Weight |
35.8 kg (79 lb.) (minimum) 44 kg (97 lb.) (fully configured) |
Power cord |
2.5 m (8.2 ft) |
Clearance and Service Access |
Front |
36 in. |
Rear |
36 in. |
Rack Mounting |