SUN  X4170 M2
SM110517
½Å»óÇ°
CPU Max 2P, up to 6C
MEM 18Slot (Max 144GB)
HDD 8 x 2.5
   
Àç°í 1 EA (½ÇÁ¦¼ö·®Àº ´Ù¸¦¼ö ÀÖÀ¸´Ï ¹®Àǹٶø´Ï´Ù.)
   
¼ö·® :  
Processor
Number 1 to 2 Quad-Core or 6-Core
Architecture Type: Intel Xeon Quad-Core or 6-Core Processors
CPUs Intel 2.40GHz Quad-Core Xeon L5620 (12MB L2, 80W)
Intel 2.26GHz 6-Core Xeon L5640 (12MB L2, 60W)
Intel 2.93GHz 6-Core Xeon E5670 (12MB L2, 95W)
Main Memory
Capacities Total DIMM slots: 18
DIMM type: DDR3 1066MHz or 1333MHz Registered DIMMs
DIMM size: 4-GB 1333MHz or 8-GB 1066MHz
Maximum capacity: 144GB (when configured with 8-GB DIMMs)
Standard Integrated Interfaces
Network Four 10/100/1000 Base-T Ethernet Ports
Network Management One dedicated 10/100Base-T Ethernet port
Serial Management One dedicated TIA/EIA-232-F asynchronous RJ45 port
SAS Four channel SAS interface, internal access only
USB Front: Two USB 2.0 ports
Rear: Two USB 2.0 ports
Internal: One USB 2.0 port (for a USB thumb drive)
PCI Expansion Slots Three low profile PCI Express 2.0 slots (1 x16 electrical/mechanical, 2 x8 electrical/mechanical)
Internal Mass Storage
Disks SAS: Up to eight front accessible disk bays with 2.5" SAS or SATA disks or four solid-state drives (SSDs) with add-on SAS Host Bus Adapter
Drive Type
Density
Speed
Form Factor
SAS
146 GB
10,000 RPM
2.5"
SAS
300 GB
10,000 RPM
2.5"
SAS
600 GB
10,000 RPM
2.5"
SATA
500 GB
7,200 RPM
2.5"
Solid State Drive
32 GB
NA
2.5"
FMOD: Up to two 24GB flash memory modules (An optional energy storage module (ESM) is required).
DVD-ROM One SATA DVD+/-RW drive
Power Supplies
Dual redundant, hot swappable power supplies
(Power supply rating output = 760W)
(UL Maximum AC input = 760W x 1.33 efficiency = 1010W)
(9.0 Amps RMS at 100 VAC)
Environment
AC power 100-120 / 200-240 VAC (50-60 Hz)
Temperature Single, non-rack system:
Operating: 5¡Æ C to 35¡Æ C (41¡Æ F to 95¡Æ F)
Nonoperating: -40¡Æ C to 70¡Æ C (-40¡Æ F to 158¡Æ F)
Humidity Single, non-rack system:
Operating: 10% to 90% relative humidity noncondensing, 27¡Æ C (80.6¡Æ F) max wet bulb
Nonoperating: up to 93% relative humidity noncondensing, 38¡Æ C (100.4¡Æ F) max wet bulb
Altitude Single, non-rack system:
Operating: up to 3000 m (9,843 ft.), maximum ambient temperature is derated by 1¡Æ C per 300 m above 900 m
Nonoperating: up to 12,000 m (40,000 ft.)
Regulations
Meets or exceeds the following requirements:
RoHS Compliance Level RoHS:YL
Safety UL 60950-1 2nd Ed, EN60950-1:2006 2nd Ed, CB Scheme with all country differences
RFI/EMI FCC CFR 47 Part 15 Subpart B Class A, EN55022:2006+A1:2007 Class A, EN 61000-3-2, EN61000-3-3, EN 300-386
Immunity EN55024, EN300-386
Certifications Safety: UL/cUL, UL DEMKO, CE, BSMI, CCC, GOST-R, S-Mark
EMC: CE, FCC, VCCI, ICES, C-Tick, MIC, CCC, GOST-R, BSMI Class A
Dimensions and Weight
Height 43.43 mm (1.71 in.)
Width 425.5 mm (16.75 in.)
Depth 685.8 mm (27.0 in.)
Weight 16.36 kg (36 lb.) maximum assuming PCI-Express card weighs 0.12 kg
(0.25 lb) each, and without the rack mounting slide rail kit installed.
Rack Mounting
Sun Fire X4170 M2 Server Racks Racks are as follows:
  • Sun Rack 938
  • Sun Rack 1038
  • Sun Rack 1042
  • Sun Rack II 1042
  • Sun Rack II 1242