Processor |
Number |
Up to eight |
Architecture |
750 MHz UltraSPARC[tm] III (64-bit) 900 MHz UltraSPARC III (64 bit) 1050 MHz UltraSPARC III (64 bit) 1200 MHz UltraSPARC III (64 bit) |
Memory Management |
MMU with 64 I-TLB entries and 64 D-TLB entries, 8192 hardware-supported contexts |
Cache memory |
64-KB data and 32-KB instruction on chip per processor
Secondary: 8-MB external per processor |
Main Memory |
Capacities |
Total of 16 DIMM memory slots available per CPU/Memory board
128, 256, 512 MB, or 1GB* (16GB maximum per CPU/Memory board, 64GB maximum when configured with 8 processors)
* - 1GB DIMMs are not supported on 750MHz CPU/Memory boards. Note: Install DIMMs in groups of four. 1050MHz and faster CPU/Memory boards require that all memory DIMM slots be fully populated. |
Memory type |
232-Pin 7-nS memory modules |
Standard Interfaces |
Ethernet |
- One Gigabit ethernet (1000BASE-SX) dual SC fiber optic port
- One ethernet/fast ethernet (10BASE-T/100BASE-T) twisted-pair standard connector (RJ-45)
|
Keyboard and mouse |
USB (uses one of the two standard USB (Type A) port) |
PCI |
Nine full sized, hot-swap, PCI slots compliant with PCI specification Revision 2.1:
- Seven slots operating at 33MHz, 64 or 32 bits wide, 5 volts
- Two slots (slots 7 and 8) operating at 33 or 66MHz, 64 or 32 bits wide, 3.3 volts
|
Remote System Controller |
One RSC card plugs into a dedicated slot on the system I/O board which includes integrated modem, serial and Ethernet interfaces.
- One 56 Kbps modem port (RJ-11)
- One EIA-232D serial port (RJ-45)
- One 10 Mbps Ethernet port (RJ-45)
|
Serial |
Two RS-232D/RS-423 serial ports (DB25) via splitter cable (X985A) |
USB |
Two standard Universal Serial Bus (USB) Type A connectors |
Internal Mass Storage |
Host Adapters |
Internal SCSI to support the internal DVD and optional removable media devices
Up to nine PCI-to-dual FC-AL adapters or PCI-to-UltraSCSI adapters |
Disks |
Up to 12 3.5" x 1" 10000 RPM FC-AL disks, 36.4GB, 73.4GB, and 146GB capacity. Maximum total capacity of 1.7TB. |
DVD-ROM |
10X DVD-ROM (standard) |
Tape |
Optional 12GB DDS3 4mm, 20GB DDS4 4mm single drive, or 4mm DAT 72 SCSI Tape |
Power Supplies |
Type |
2 minimum, 3 for N+1 redundancy, individual power cords |
Output |
1100W maximum per power supply |
Environment |
AC input |
100 - 240 VAC, 47 - 63 Hz, 15 A (max) per power cord, 1.48 KVA per power supply (3.0 KVA) |
Input power |
2880 W (max), using 1050 or 1200 MHz CPUs |
Heat output |
9829 BTU/hr (max), using 1050 or 1200 MHz CPUs Note: See How To article 1004780.1 for details. |
Temperature |
Operating: 5¡Æ C to 35¡Æ C (41¡Æ F to 95¡Æ F) Nonoperating: -20¡Æ C to 60¡Æ C (-4¡Æ F to 140¡Æ F) |
Humidity |
Operating: 20% to 80% relative humidity, noncondensing Nonoperating: 5% to 93% relative humidity, noncondensing |
Altitude |
Operating: 3000 m (10,000 ft.) Nonoperating: 12,000 m (40,000 ft.) |
Acoustic noise |
Operating: 66.5 dBA ok prompt: 75.7 dBA |
Vibration |
Operating: 0.0002 G2/Hz, 5 - 500 Hz (random) (deskside) 0.00015 G2/Hz, 5 - 500 Hz (random) (rackmounted) Nonoperating: 0.002 G2/Hz, 5 - 500 Hz (random) (deskside) 0.0015 G2/Hz, 5 - 500 Hz (random) (rackmounted) |
Shock |
Operating: 4 G peak, 11 milliseconds half-sine pulse (deskside) 3 G peak, 11 milliseconds half-sine pulse (rackmounted) Nonoperating: 15 G peak, 11 milliseconds half-sine pulse (deskside) 10 G peak, 11 milliseconds half-sine pulse (rackmounted) |
Number of cords |
3 |
Regulations Meets or exceeds the following requirements: |
Safety |
UL 60950, CSA C22.2, EN 60950 (from UL), TUV 60950, UL CB Scheme IEC 950 (CE Mark), GOST |
RFI/EMI |
Class A:Australia/New Zealand AS/NZ 3548, Industry Canada ICES-003,European Community EN55022/CISPR22,Japan VCCI,Taiwan CNS 13438,and US FCC 47CFR15.B |
Immunity |
EN55024,i.e.EN61000-4-2,EN61000-4-3, EN61000-4-4,EN61000-4-5,EN61000-4-6, EN61000-4-8,and EN61000-4-11 |
X-ray |
US DHHS 21 CFR Subchapter J, PTB German X-ray Decree |
Dimensions and Weights |
Height1 |
71.4 cm (28.1 in.) with castors |
Width |
48.0 cm (18.9 in.) |
Depth |
83.6 cm (32.9 in.) |
Weight |
88.1 kg (194.0 lb.)(minimum, approximate) 130.9 kg (288.0 lb.)(maximum, approximate) |
Power Cord |
2.5 m (8.2 ft.) |
1 Rackmounting does not require the removal of castors. |
Clearance and Service Access |
Front |
Deskside - 91 cm (36 in.) Rackmount - 122 cm (48 in.) |
Rear |
91 cm (36 in.) |
Right |
91 cm (36 in.) |
Left |
91 cm (36 in.) |
Rack Mounting |
Fits into Sun StorEdge 72" Expansion Rack, Sun Fire Cabinet, Sun Rack 900, & standard commercial 19-inch wide, 36-inch deep racks, but in third party racks, the front and rear doors must be at least 63% open area for the Sun Fire V880 to cool properly. To facilitate rack mounting, heavier components such as power supplies may be removed. |